POST Error Code FRU/Action1117Failed baud rate test 1. Run Enhanced Diagnostics1162Serial port configuration error 1. Run Configuration2. Serial Adapter(if installed)3. System Board11XXNot listed above 1. System Board1201 1. System Board2. Any Serial Device1202, 1206, 1208, 1209, 12XX 1. Dual Async Adapter/A2. System Board3. Any Serial Device1207 1. Communications Cable2. Dual Async Adapter/A13XX 1. Game Adapter1402Printer not readyInformation only1403No paper error, or interrupt failureInformation only1404System board timeout failure 1. Run Enhanced Diagnostics1405Parallel adapter error 1. Run Enhanced Diagnostics1406Presence test error 1. Run Enhanced Diagnostics14XXNot listed above. Check printer beforereplacing system board1. Printer2. System Board15XX 1. SDLC Adapter1692Boot sequence error 1. Run FDISK to ensure at least one activepartition is set active16XX 1. 36/38 Workstation Adapter1762Hard disk drive configuration error 1. Run Configuration. (See “Setup Utilityprogram” on page 10.)1780 (Disk Drive 0)1781 (Disk Drive 1)1782 (Disk Drive 2)1783 (Disk Drive 3)1. Hard Disk Drive2. System Board3. Riser card4. Hard Disk Cable5. Power Supply98 Hardware Maintenance Manual