Diagnostic error codesRefer to the following diagnostic error codes when using the diagnostic tests. See″Diagnostics″ on page 9 for the specific type for information about the Diagnosticprograms.In the following index, X can represent any number.Diagnostic Error Code FRU/Action000-000-XXXBIOS Test Passed 1. No action000-002-XXXBIOS Timeout 1. Flash the system2. System board000-024-XXXBIOS Addressing test failure 1. Flash the system2. System board000-025-XXXBIOS Checksum Value error 1. Flash the system2. Boot block3. System board000-026-XXXFLASH data error 1. Flash the system2. Boot block3. System board000-027-XXXBIOS Configuration/Setup error 1. Run Setup2. Flash the system3. Boot block4. System board000-034-XXXBIOS Buffer Allocation failure 1. Reboot the system2. Flash the system3. Run memory test4. System board000-035-XXXBIOS Reset Condition detected 1. Flash the system2. System board000-036-XXXBIOS Register error 1. Flash the system2. Boot block3. System board000-038-XXXBIOS Extension failure 1. Flash the system2. Adapter card3. System board000-039-XXXBIOS DMI data error 1. Flash the system2. System board000-195-XXXBIOS Test aborted by user 1. Information2. Re-start the test, if necessary000-196-XXXBIOS test halt, error threshold exceeded 1. Press F3 to review the log file2. Re-start the test to reset the log file72 Hardware Maintenance Manual