Diagnostic Error Code FRU/Action001-038-XXXSystem Extension failure 1. Adapter card2. System board001-039-XXXSystem DMI data structure error 1. Flash the system2. System board001-040-XXXSystem IRQ failure 1. Power-off/on system and re-test2. System board001-041-XXXSystem DMA failure 1. Power-off/on system and re-test2. System board001-195-XXXSystem Test aborted by user 1. Information2. Re-start the test, if necessary001-196-XXXSystem test halt, error threshold exceeded 1. Press F3 to review the log file2. Re-start the test to reset the log file001-197-XXXSystem test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test001-198-XXXSystem test aborted 1. If a component is called out, make sureit is connected and/or enabled2. Flash the system and re-test3. Go to the ″Undetermined problems″section001-199-XXXSystem test failed, cause unknown 1. Go to the ″Undetermined problems″section2. Flash the system and re-test3. Replace component under function test001-250-XXXSystem ECC error 1. System board001-254-XXX001-255-XXX001-256-XXX001-257-XXXSystem DMA error1. System board001-260-XXX001-264-XXXSystem IRQ error1. System board001-268-XXXSystem IRQ1 failure 1. Device on IRQ12. System board001-269-XXXSystem IRQ2 failure 1. Device on IRQ22. System board001-270-XXXSystem IRQ3 failure 1. Device on IRQ32. System boardChapter 7. Symptom-to-FRU Index 91