v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, Type 8863,” on page 93 to determine which components are customerreplaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by atrained service technician.Error code Description Action00180600 PCI built-in self-test failure. 1. If the error code indicates a particular PCI orPCI-X slot or device, remove that device.Note: Slot 0 indicates the I/O board.2. Reseat the following components:a. Each adapterb. (Trained service technician only, if thespecified board is a FRU) The board indicatedin the error code. (See Chapter 3, “Partslisting, Type 8863,” on page 93, to determineCRU or FRU status.)3. Replace the components listed in step 2 one at atime, in the order shown above, restarting theserver each time.00180700,00180800General PCI error. 1. Make sure that no devices have been disabled inthe Configuration/Setup Utility program.2. Reseat the following components:a. Failing adapterNote: If an error LED is lit on the PCI-Xboard or on an adapter, reseat that adapterfirst; if no LEDs are lit, reseat each adapterone at a time, restarting the server each time,to isolate the failing adapter.b. (Trained service technician only) PCI-X board3. Replace the components listed in step 2 one at atime, in the order shown, restarting the servereach time.00181000 PCI error. 1. Remove the adapters from the PCI or PCI-Xslots.2. Reseat the following components:a. Failing adapterNote: If an error LED is lit on the PCI-Xboard or on an adapter, reseat that adapterfirst; if no LEDs are lit, reseat each adapterone at a time, restarting the server each time,to isolate the failing adapter.b. (Trained service technician only) PCI-X board3. Replace the components listed in step 2 one at atime, in the order shown, restarting the servereach time.30 IBM xSeries 366 Type 8863: Problem Determination and Service Guide