v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, Type 8863,” on page 93 to determine which components are customerreplaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by atrained service technician.Error code Description Action166-400-000 ISMP Self Test Result failed tests: xxxwhere xxx=flash, ROM, or RAM. 1. Disconnect all server and option power cordsfrom the server, wait 30 seconds, reconnect thepower cords, and retry.2. Update the BMC firmware (see “Updating thefirmware” on page 133).3. Reseat the I/O board.4. Replace the I/O board.166-400-100 DMC Self Test Result failed tests: xxx wherexxx=flash, ROM, or RAM. 1. Disconnect all server and option power cordsfrom the server, wait 30 seconds, reconnect thepower cords, and retry.2. Update the BIOS code, BMC, service processor,and diagnostics firmware (see “Updating thefirmware” on page 133).180-197-000 SCSI ASPI driver not installed. 1. Remove the RAID adapter, if one is installed, andrun the test again.2. Reseat the following components:a. SAS hard disk drive backplane cablesb. I/O boardc. Microprocessor tray3. Replace the following components one at a time,in the order shown, restarting the server eachtime.a. SAS hard disk drive backplaneb. I/O boardc. (Trained service technician only)Microprocessor tray180-361-003 Failed fan LED test. 1. Reseat the following components:a. Fanb. I/O board2. Replace the components listed above one at atime, in the order listed above, restarting theserver each time.180-xxx-000 Diagnostics LED failure. Run the diagnostic LED test for the failing LED.Chapter 2. Diagnostics 71