Diagnostic Error Code FRU/Action011-000-XXXSerial port Interface Test Passed 1. No action011-001-XXXSerial port Presence 1. Remove external serial device, ifpresent2. Run setup, enable port3. System board011-002-XXX011-003-XXXSerial port Timeout/Parity error1. System board011-013-XXX011-014-XXXSerial port Control Signal/Loopback testfailure1. System board011-015-XXXSerial port External Loopback failure 1. Wrap plug2. System board011-027-XXXSerial port Configuration/Setup error 1. Run Setup, enable port2. Flash the system3. System board011-03X-XXX011-04X-XXXSerial port failure1. System board011-195-XXXSerial port Test aborted by user 1. Information2. Re-start the test, if necessary011-196-XXXSerial port test halt, error threshold exceeded 1. Press F3 to review the log file2. Re-start the test to reset the log file011-197-XXXSerial port test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test011-198-XXXSerial port test aborted 1. If a component is called out, make sureit is connected and/or enabled2. Flash the system and re-test3. Go to the ″Undetermined problems″section011-199-XXXSerial port test failed, cause unknown 1. Go to the ″Undetermined problems″section2. Flash the system and re-test3. Replace component under function test011-2XX-XXXSerial port signal failure 1. External serial device2. System board014-000-XXXParallel port Interface Test Passed 1. No actionChapter 6. Symptom-to-FRU Index 45