Diagnostic Error Code FRU/Action030-00X-XXX030-01X-XXXSCSI interface failure1. SCSI signal cable2. Check power supply3. SCSI device4. SCSI adapter card, if installed5. System board030-027-XXXSCSI interface Configuration/Setup error 1. SCSI signal cable2. Flash the system3. SCSI device4. SCSI adapter card, if installed5. System board030-03X-XXX030-04X-XXXSCSI interface error1. SCSI signal cable2. Check power supply3. SCSI device4. SCSI adapter card, if installed5. installed System board030-195-XXXSCSI interface Test aborted by user 1. Information2. Re-start the test, if necessary030-196-XXXSCSI interface test halt, error thresholdexceeded1. Press F3 to review the log file2. Re-start the test to reset the log file030-197-XXXSCSI interface test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test030-198-XXXSCSI interface test aborted 1. If a component is called out, make sureit is connected and/or enabled2. Flash the system and re-test3. Go to the ″Undetermined problems″section030-199-XXXSCSI interface test failed, cause unknown 1. Go to the ″Undetermined problems″section2. Flash the system and re-test3. Replace component under function test035-000-XXXRAID interface Test Passed 1. No action035-0XX-XXXRAID interface Failure 1. RAID signal cable2. RAID device3. RAID adapter card, if installed4. System board035-195-XXXRAID interface Test aborted by user 1. Information2. Re-start the test, if necessary50 Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer