POST Error Code FRU/Action08XCheck SCSI terminator installation. 1. SCSI Cable2. SCSI Terminator3. SCSI Device4. SCSI Adapter101System board interrupt failure 1. System Board102System board timer error 1. System Board106 1. System Board110System board memory parity error 1. Memory Module2. System Board111I/O channel parity error 1. Reseat adapters2. Any adapter3. Riser card4. System Board114Adapter ROM error 1. Adapter Memory2. System Board3. Riser card129Internal cache test error 1. Processor2. L2 Cache Memory3. System Board151Real-time clock failure 1. System Board161Bad CMOS battery 1. Run Setup2. CMOS Backup Battery (see “SafetyInformation” on page 125)3. System Board162Configuration mismatch 1. Run Setup and verify Configuration2. Had a device been added, removed,changed location? If not, suspect thatdevice.3. Power-on external devices first, thenpower-on computer4. CMOS Backup Battery (see “SafetyInformation” on page 125)System Board5. System Board6. Riser card162And unable to run diagnostics 1. Diskette Drive2. System Board3. Diskette Drive Cable4. Riser card60 Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer