Note: You might need to remove the blue latch from PCI riser-card assembly 2to easily connect the cables.8. Perform any configuration tasks that are required for the adapter.ResultsIf you have other devices to install or remove, do so now. Otherwise, go to“Completing the installation” on page 96.Installing a ServeRAID SAS/SATA controllerUse this information to install a ServeRAID SAS/SATA controller.About this taskNote: For brevity, in this documentation the ServeRAID SAS/SATA controller isoften referred to as the SAS/SATA adapter or the ServeRAID adapter.The ServeRAID SAS/SATA controller can be installed in the dedicated connectoron the system board or PCI riser-card slots (see “System-board internal connectors”on page 28 for the location of the connectors). To install a SAS/SATA adapter,complete the following steps:Depending on the server model, the server comes with a ServeRAID H1110, aServeRAID M1115, a ServeRAID M5110, or a ServeRAID 5210 SAS/SATA adapterinstalled.Note: Remove the PCI bracket that come with ServeRAID H1110, ServeRAIDM1115, ServeRAID M5110 SAS/SATA, or a ServeRAID 5210 adapter beforeinstalling a SAS/SATA adapter in the dedicated connector on the system board.Attention:v You can not install ServeRAID H1110 when microprocessor Intel Xeon E5-2637(FRU part number 49Y8124) is installed.v You can not install ServeRAID M1115 or IBM 6Gb performance optimized HBAwhen Quadro 2000 is installed.You can replace the ServeRAID controller with another supported ServeRAIDcontroller. For a list of supported ServeRAID controllers, see http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.Figure 40. Latch removalChapter 2. Installing optional devices 59