A single problem might cause more than one error message. When this happens,correct the cause of the first error message. The other error messages usually willnot occur the next time you run the diagnostic programs.Exception: If there are multiple error codes or diagnostics LEDs that indicate amicroprocessor error, the error might be in a microprocessor or in a microprocessorsocket. See “Microprocessor problems” on page 128 for information aboutdiagnosing microprocessor problems.If the server stops during testing and you cannot continue, restart the server and tryrunning the diagnostic programs again. If the problem remains, replace thecomponent that was being tested when the server stopped.Diagnostic text messagesDiagnostic text messages are displayed while the tests are running. A diagnostictext message contains one of the following results:Passed: The test was completed without any errors.Failed: The test detected an error.User Aborted: You stopped the test before it was completed.Not Applicable: You attempted to test a device that is not present in the server.Aborted: The test could not proceed because of the server configuration.Warning: The test could not be run. There was no failure of the hardware that wasbeing tested, but there might be a hardware failure elsewhere, or another problemprevented the test from running; for example, there might be a configurationproblem, or the hardware might be missing or is not being recognized.The result is followed by an error code or other additional information about theerror.Viewing the test logTo view the test log when the tests are completed, select Utility from the top of thescreen and then select View Test Log. The summary test log is displayed. To viewthe detailed test log, press the Tab key while viewing the summary log.The test-log data is maintained only while you are running the diagnostic programs.When you exit from the diagnostic programs, the test log is cleared.To save the test log to a file on a diskette or to the hard disk, click Save Log on thediagnostic programs screen and specify a location and name for the saved log file.Notes:1. To create and use a diskette, you must add an optional external diskette drive tothe server before you turn it on.2. To save the test log to a diskette, you must use a diskette that you haveformatted yourself; this function does not work with preformatted diskettes. If thediskette has sufficient space for the test log, the diskette can contain other data.Chapter 5. Diagnostics 143