VAC-5000HD User’s Guide217.2 Setting input and output (Setting menu)7.2.1 [F01 to F03] Copying EDIDNote: “[ ]” shows each menu number in this chapter.EDID of sink devices can be read and saved, and three EDID can be registered in the VAC as same asinternal EDID.(1) Select the sink device whose EDID will be copied and press the “SET” key to register it.Menu number: [F01 to F03](2) Select the copy data you want to use.Menu number: [F14](3) Select “02” for the EDID setting.Menu number: [F10][Fig. 7.1] Copying and saving EDIDMenu numbersF01 to F03: Copied data 1 to 3Setting values01 to 05: OUT1 to OUT5 [Default: OUT1]Note: If cascade connection is employed, the source device will read the EDID of the source-device-sideVAC-5000HD. In order to enable the source device to read the EDID of the sink device, follow theprocedure below.(1) Copy the EDID of the sink device into the sink-device-side VAC-5000HD and set it as “Copied EDID”or “EXTERNAL (External EDID)”.(2) Copy the EDID of the sink-device-side VAC-5000HD into the source-device-side VAC-5000HD andset it as “Copied EDID” or “EXTERNAL (External EDID)”.Computer (Source device side) (Sink device side)VAC-5000HD VAC-5000HDProjectorONOFFDISTRIBUTION AMPLIFIER for HDMI VAC-1000HDPOWER SIGNALONOFFDISTRIBUTION AMPLIFIER for HDMI VAC-1000HDPOWER SIGNAL[Fig. 7.2] Reading EDIDtoOUT 1OUT 5LC monitorCopied data 1Copied data 2Copied data 3Copied EDIDEXTERNAL EDIDInternal EDIDBlu-ray disc player Step 1Step 2Step 3