IDS 1632 Installer Manual 700-256-02K Issued September 2009 24Sub-location 9 Swinger Shutdown Reporting CodeThe swinger shutdown zone code will be reported if the system is armed and a zone is automaticallybypassed as a result of multiple violations of that zone.Sub-location 10 Swinger Shutdown Restore Reporting CodeIf enabled, this code will be reported when a swinger shutdown zone is automatically restored i.e. un-bypassed.Sub-location 11 Zone Programmable Output LocationA programmable output will be pulsed or latched, high or low if a zone causes an alarm condition. Ifpulsed, the output will be pulsed for the time programmed in Sub-location 1 of Locations 388 - 399.Two digits must be programmed for each zone. The first digit references the programmableoutput number e.g. output 1 to 5 (7 with an expander). The second digit sets the output action. Refer“System Programmable Outputs” (Page 32) for a detailed description on Programming ProgrammableOutputs.Sub-location 12 Zone Name Editing (Only with LCD keypads)Zones may be given appropriate names, like “Front Door” for zone 1, etc. When the zone is triggered, thedisplay will indicate “Front Door”, instead of “Zone 1”. (Full instructions are included in the LCD keypadmanual.)7.6.2 System OptionsLOCATION 33 Zone Shutdown Count (Default = 5)Determines the number of times a zone may be violated during an arm cycle before it is automaticallybypassed. Select zones individually for this option in locations 1 – 32s (Sub-location 2). Valid range ofdata for this location is 1 to 15.LOCATION 34 Programmable Zone Loop Response TimeValue Response Time Value Response Time0 6 ms 8 96 ms1 12 ms 9 108 ms (default)2 24 ms 10 120 ms3 36 ms 11 132 ms4 48 ms 12 144 ms5 60 ms 13 156 ms6 72 ms 14 168 ms7 48 ms 15 180 msThe zone loop response is the period of time for which the programmed zone must remain violatedbefore a violation is registered. Unless the Second Loop Response Time is selected, this location willdetermine the response time.