IDS 1632 Installer Manual 700-256-02K Issued September 200933When programming a programmable output whose action is fixed only a single digit need be entered.This digit references the programmable output number (Table 5).Example:Programming a value of [7] into Sub-location 42 of Location 129 will cause the Zone ExpanderProgrammable Output 1 to follow the Siren Output for Partition 2.NOTE:When connecting any device with a high current requirement to a programmable output a suitable relaymust be used. DO NOT connect such devices directly to the programmable outputs as this may damagethe output circuitry.LOCATIONS 70 - 87 Event Driven Programmable OutputsTable 7 : Event Driven Programmable OutputsLoc. Event Output Default Action70 AC Fail Programmable Output disabled71 AC Restore Programmable Output disabled72 Low Battery Programmable Output disabled73 Battery Restore Programmable Output disabled74 Auto Test Programmable Output disabled75 Download Programmable Output disabled76 Siren Trouble Programmable Output disabled77 Aux 12V Trouble Programmable Output disabled78 Keypad Fuse Programmable Output disabled79 485 Device Tamper Programmable Output disabled80 485 Bus Failure Programmable Output disabled81 Box Tamper Programmable Output disabled82 Dedicated Panic Programmable Output 1 Pulse High [2]83 Communication Fail Programmable Output disabled84 Phone Line Tamper Programmable Output disabled85 Phone Line Restore Programmable Output disabled86 RF Jamming Programmable Output disabled87 RF Jamming Restore Programmable Output disabledLOCATIONS 95 – 96 Function Driven Programmable OutputsTable 8 : Function Driven Programmable OutputsSummary of System function Driven Programmable outputsLoc. Function Output95 Fire Sensor Power Programmable Output Disabled96 Dual Reporting Programmable Output Disabled