11416TROUBLESHOOTING12345678910111213141516PROBLEM POSSIBLE CAUSE SOLUTION REF.The transceiver doesnot turn ON.• Bad connection to the power supply. • Check the connection to the transceiver andpower supply.p. 101Little or no sound comesfrom the speaker.• Squelch level is set too high.• Volume level is set too low.• Speaker has been exposed to water.• Set the squelch to the threshold point.• Set the volume to a suitable level.• Remove the water with the AquaQuake func-tion.p. 3p. 4p. 15Transmitting is impossi-ble, or high power can-not be selected.• Some channels are programmed for lowpower or receive only by regulations.• The output power is set to low.• Change channels.• Push [HI/LO] to select high power.pp. 9,10, 11p. 11Scan does not start. • More than 2 favorite channels are not pro-grammed.• Set the desired channels as Favorite chan-nels.p. 17No beep sounds. • Beep tones are turned OFF. • Turn the beep tones ON in the CONFIGURA-TION menu.p. 93Distress calls cannot betransmitted.• MMSI (DSC self ID) code is not pro-grammed.• Program the MMSI (DSC self ID) code. p. 8Does not record or doesnot record properly.• The memory IC is not working. • The memory IC should be replaced.Ask your service center or technical dealerfor details.—