offered by Busse-Yachtshop.com276DSC OPERATION6 Receiving DSC callsDD Receiving a distress callWhile monitoring Channel 70 and a distress call is received:➥ The emergency alarm sounds for 2 minutes.• Push any switch to stop the alarm.➥ “Received Distress” appears in the display, thenChannel 16 is automatically selected.➥ Continue monitoring Channel 16 as a coast station may re-quire assistance.DD Receiving a distress acknowledgementWhile monitoring Channel 70 and a distress acknowledge-ment to other ship is received:➥ The emergency alarm sounds for 2 minutes.• Push any switch to stop the alarm.➥ “Received Distress ACK” appears in the display,then Channel 16 is automatically selected.DD Receiving an all ships callWhile monitoring Channel 70 and an all ships call is received:➥ The emergency alarm sounds when the category is ‘Dis-tress’ or ‘Urgency’; 3 beeps sound for other categories.➥ “Received All Ships” appears in the display, thenChannel 16 is automatically selected for voice communica-tion.➥ Monitor channel 16 for an announcement from the callingvessel.BUSY-25W---INT---CALLLOCAL--DUPSCRAM--TAGReceivedCANAll Ships>- --CALLINGBUSY-25W---INT---CALLLOCAL--DUPSCRAM--TAGReceivedCANDistressACK>Chuck3---CALLINGBUSY-25W---INT---CALLLOCAL--DUPSCRAM--TAGReceivedCANDistress---CALLING