3010 OTHER FUNCTIONS Auto power-off functionThe transceiver can be set to automatically turn OFF after aspecified period in which no switch is pushed.120 min., 90 min., 60 min., 30 min. and OFF can be speci-fied. The specified period is retained even when the trans-ceiver is turned OFF by the auto power-off function. To cancelthe function, select “OFF” in step e below.q Push [V/M] for 2 sec. to enter expanded set mode.w Rotate [DIAL] until “AP OFF” appears.• Turn the expanded set mode ON for selection. (p. 28)• “AP OFF” disappears after 1 sec. and “AO” appears.e While pushing [FUNC], rotate [DIAL] to select the desiredtime or to turn the function OFF.r Push [V/M] to exit set mode. Monitor switch functionThe monitor switch can be set as a sticky switch. When set tothe sticky condition, each push of [SQL] toggles the monitorfunction on and off.q Push [V/M] for 2 sec. to enter expanded set mode.w Rotate [DIAL] until “MONI” appears.• Turn the expanded set mode ON for selection. (p. 28)• “MONI” disappears after 1 sec. and “mO” appears.e While pushing [FUNC], rotate [DIAL] to set the monitorswitch to sticky (HOLD) or normal (PUSH).r Push [V/M] to exit set mode.60 min. auto power-offAuto power off setmodeAuto power-off isturned OFF.Sticky switchMonitor switchfunction set modeNormal switch