JCM Part No. 960-000097R_Rev. 3 © 2010, JCM American, Corporation6 - 6Section 6 Universal Bill Acceptor (UBA-1x-SS & UBA-x4-SS/SU) Programming, Calibration & Test7. After a short period, the Dialog Box Windowwill indicate "Black Adjustment" (See Figure6-17). Open the UBA's Upper Guide,remove the White Reference Paper andinsert the Black Reference Paper (See Figure6-19 ), firmly close the guide (See Figure6-19 ) and Mouse-click the OK ScreenButton again.8. Repeat the White and Black Reference Papersteps as instructed on the Screen until the"UV Adjustment" Screen shown in Figure 6-20 is displayed. Open the UBA UpperGuide, remove the existing test ReferencePaper and insert the UV Reference Paper inits place; then Mouse-click on the OK ScreenButton again.9. Insert the UV Reference Paper so it coversthe White Plastic Area at the rear center ofthe Lower Transport path (See Figure 6-21) with the Label facing UP, and firmlyclose the Upper Guide as shown in Figure 6-21 , then Mouse-click on the OK ScreenButton again.10. When the "Adjustment Without ReferencePaper" Screen appears, open the UpperGuide and remove the UV Reference Paper,then firmly close the Upper Guide andMouse-click on the OK Screen But-ton again (See Figure 6-22).11. When the White Adjustment Screen reap-pears, insert the White Reference paper andagain Mouse-click on the OKScreen Button.12. When adjustment of all of the Optical Sen-sors is complete, the "MAG HEAD Adjust-ment" Screen will appear (See Figure 6-23).Figure 6-18 White Test Paper Insertion RequestFigure 6-19 Black Test Paper Insertion RequestFigure 6-20 Set UV Reference Test ScreenFigure 6-21 UV Test Paper Insertion RequestCAUTION: Do not insert the UVReference paper past the curved areaof the Transport, an error will occur ifthe UV Reference paper is inserted intoo far.Figure 6-22 Remove UV Reference Test Screen