INSTALLATION8For Aero Select, Laser Select, Santina Select and Solaris Select:Electrical Conversion from 50 AMP to 30 AMP OperationYour spa, as it comes from the factory, requires a 230 VAC, 50 AMP, 4-wire, grounded type GFCI (Ground FaultCircuit Interrupter) protected electrical service. If you prefer, the spa can be converted to operate with a 230 VAC, 30AMP electrical service. The conversion must be made by a qualified electrician. After conversion following thisprocedure, the spa heater will automatically be turned OFF whenever either the high speed jets or the air blower isactivated.To convert to 230 VAC, 30 AMP operation:1. Turn OFF breaker at main electrical power.2. Open the skirt door access panel.3. Loosen and remove 4 screws securing the electrical cabinet cover and set them aside.4. Move the jumper at circuit board location J8 from the 50A position to the 20A position. Refer to Figures 1 and 2.5. Replace electrical cabinet cover and tighten the screws.6. Test for proper operation of the GFCI before using the spa. Refer to the installation instructions for proper testprocedure.20A50AJ8MOVE THEJUMPER ATLOCATION J8FROMTOP 50ATERMINAL TOBOTTOM 20ATERMINALFIGURE 2 FIGURE 350A20AJ8SEE FIGURE 2FIGURE 1