Page 56B. To drain your spa, perform the following steps (QuickDrain):1. Turn off power to hot tub at the breaker.2. You must first remove the corner panels inorder to remove the center panel, Figure13.2e.3. Grab one of the corner panels, from thebottom, where it touches the bottom pan.Then gently pull the panel forward tounsnap it from the holding clip. Place thecorner panel in a safe location to preventfrom damaging it. Repeat the steps toremove the other corner panel.4. Now you need to remove the center panel.Grab the sides of the panel and gentlypull the cabinet forward until all the clipshave been release then pull up to remove,Figure 13.2f. Place the panel in a safelocation to prevent from damaging it.5. Locate the QuickDrain valve, Figure 13.2g.6. Unscrew drain valve cap, Figure 13.2h.Place the cap aside.7. Screw in the adapter with hose that was included inthe equipment bay; attach it to the QuickDrain, Figure13.2i. Make sure to direct the hose to an area wherethe water will drain properly.8. Open the drain slice valve by sliding the handle to theside and pulling up.9. After the hot tub has drained close the slice valveby pushing it downward and sliding the handle to theside. Remove the adapter and reinstall the QuickDrain capbefore refilling hot tub.After refilling, turn on power to the spa and follow the stepslisted under “Spa Fill Up Procedures” (page 17). Always fillyour spa through both filter buckets.13.3 Cleaning the Spa InteriorTo preserve the sheen of your spa’s surface, it is crucial that you avoidusing abrasive cleaners or cleaners which have adverse chemical effecton the surface. If you are not certain as to the suitability of a particularcleanser, consult your authorized Jacuzzi dealer. We recommend usingJacuzzi’s Spa All Purpose Cleaner to clean the spa’s interior surface.Use extreme care to assure that no soap residue is left on the surface.This could cause severe sudsing when the spa is refilled. Jacuzzichemicals are for use in the U.S. only.Figure 13.2eFigure 13.2fFigure 13.2gFigure 13.2iPoweronLamponDANGER!TURN POWEROFF! DO NOTLOOK AT LIT BULB.SEVERE EYEDAMAGE OR BLINDNESSCAN OCCUR!Figure 13.2h