Page 22 FloPro Series Pumps Installation and Operation Manual7.4 Physical and Operational Specifications7.4.1 SpecificationsModel No. HP Voltage Amps Pipe Size Carton Weight Overall Length 'A'FHPM .75 0.75 230/115 5.4/10.8 1½-2" 40.6 25 3/16"FHPM 1.0 1.00 230/115 7.1/14.2 2-2½" 41.2 25 3/16"FHPM 1.5 1.50 230/115 8.0/16 2-2½" 42.6 25 ½"FHPM 2.0 2.00 230/115 11.2/22.4 2-2½" 54.6 27 3/16"FHPM 2.5 2.50 230 11.5 2½-3" 48.6 26 3/16"FHPM 1.0-2-SPD 1.00 230 7.1/2.3 2½-3" 46.5 26 5/16"FHPM 1.5-2SPD 1.50 230 8.0/3.0 2½-3" 48.0 26 9/16"FHPM 2.0-2SPD 2.00 230 11.2/3.5 2½-3" 52.9 27 11/16"7.4.2 DimensionsTable 5 shows the height of the FHP pump in the three (3) mounting configurations listed below. Figures 2, 3 and6, on page 9, show drawings of these three (3) configurations.1) Without the FHP base2) With the FHP base3) With the FHP base and spacersThe width of the FHP base (with or without spacers) is 8⅞".Table 5. FHP Mounting ConfigurationsFHP Mounting Configurations Suction Side Height Pump HeightFHP Pump without Base 7 ¾" 12¾"FHP Pump with Base 8⅞" 13⅞"FHP Pump with Base and Spacers 9⅛" 14⅛"Figure 16 shows the dimensions (height, width, and length) of the FHP pump without the FHP base and spacers.6 ¾"7 ¾"10"10 ⅞"7 ¾"12 ¾"11 ⅛"'A'NOTE See Table 3, column 7 for the value of 'A'.Bolt Holes,Center to Center Front Edge of Union,to Center of Bolt HolesNOTE When installing the pump, leave a minimum of two feet (2 ft) of clearanceabove the pump for removal of the strainer basket.Figure 16. FHP Pump Dimensions (without Base or Spacers)Table 4. FHPM Pump Specifications