Page 9FloPro Series Pumps Installation and Operation Manual3.1.3 Replacement of Existing PumpJandy FHP pumps can easily replace severalother pumps: the Hayward® Super Pump ®, Pentair®SuperFlo®, Pentair® WhisperFlo®, Jandy PlusHP (PHP),and Jandy MaxHP (MHP).To replace the Pentair® WhisperFlo®, Jandy PHP,or Jandy MHP, use the FHP’s adjustable base. The FHPbase (and its spacers) increase the total height of thepump and the height of the suction side of the pump.See Table 1.Table 1. FHP DimensionsBase Configuration Suction SideHeightPumpHeightPump without Base 7 ¾" 12¾"Pump with Base 8⅞" 13⅞"Pump with Base and Spacers 9⅛" 14⅛"3.1.3.1 Hayward ® Super Pump® andPentair ® SuperFlo®The Jandy FHP can replace a Hayward® SuperPump® or a Pentair® SuperFlo ® without using the FHPbase. See Figure 2.7 3/4"12 3/4"Figure 2. Place FHP Directly on Equipment Pad8 7/8"13 7/8"Figure 3. Place FHP with Base on Equipment PadXXCutspacersat X.Figure 4. Cut Sets of Spacers Out of BaseFigure 5. Snap Spacers into Place9 1/8"14 1/8"Figure 6. Place FHP with Base and Spacers onEquipment Pad3.1.3.2 Pentair ® WhisperFlo® PumpTo replace a Pentair® WhisperFlo® pump with aJandy FHP, place the FHP base on the equipment padand place the FHP on the base, as shown in Figure 3.3.1.3.3 Jandy PlusHP (PHP) andJandy MaxHP (MHP)To replace a Jandy PHP or Jandy MHP pump with aJandy FHP, use the FHP base with spacers.1. Using a hand cutter tool, cut the plastic barsconnecting the top and bottom sets of spacers, asshown in Figure 4.2. Push the two (2) top spacers and two (2) bottomspacers out of the base.3. Align the pins in the four (4) spacers with theholes in the base and snap the spacers into place,as shown in Figure 5.4. Place the FHP on the base assembly. See Figure 6.Hayward and Super Pump are registered trademarks of HaywardIndustries, Inc.Pentair is a registered trademark of Pentair, Inc.SuperFlo and WhisperFlo are registered trademarks of Pentair WaterPool and Spa, Inc.