Page 18ENGLISH Nicheless Underwater LED Lights | Owner’s Manual NicheSection 10. TroubleshootingUse the troubleshooting information in the following table for suggestions.Symptom Problem Corrective ActionAll lights fail to illuminate Lights are not reciev-ing powerCheck 120VAC power supplyinto transformer. Check for12VAC output at transformer.Check or reset GFCI. Makesure 120 volts has not beenused in the installation - if sodamage is assured and is NOTWARRANTABLE.One or more lights aredim, blinking or notworkingPoor connection orimproper wire gaugeSeparate each light andindependently wire 12V to thesingle light only. Repeat thisprocess on each light. If junc-tion box is being used, checkfor proper connection of lightcord. Verify that the correct wiregauge is being used betweenthe transformer and junctionbox.Colored lights out ofsynchImproper voltagesupply or poor con-nection to the lightVerify that proper wire connec-tions are being achieved forthe lights that are out of sync.Reset all the lights to white byturning lights OFF for five (5)seconds, then turning ONLight is blinking Light is too hot Confirm that the light issubmerged in water that doesnot exceed a temperature of104F (40C)