©2005 Maytag Services 16025927 21To avoid risk of electrical shock, personal injury ordeath; disconnect power to unit before servicing.Disassembly ProceduresTransformer1. Remove power from unit.2. Remove back panel, see "Back Panel" procedure.3. Label and disconnect wire terminals from cooling fan.4. Remove screws securing fan to range chassis.5. Reverse procedure to reinstall cooling fan.Bake Element1. Remove power from unit.2. Open oven door and remove rack(s).3. Remove screws securing bake element to rear ofcavity wall.4. Pull element forward to allow disconnection ofterminals on each element leg.5. Reverse procedure to reinstall bake element.Broil Element1. Remove power from unit.2. Remove screws securing broil element to top andrear of oven cavity.3. Pull broil element forward to allow disconnection ofterminals on each element leg.4. Reverse procedure to reinstall broil element.Downdraft Blower Motor (Select Models)1. Remove power from unit.2. Remove bottom access panel, see "Bottom AccessPanel" procedure.3. Disconnect ducting allow for downdraft blower motorremoval.4. Label and disconnect electrical connections.5. Remove screws securing motor assembly.6. Reverse procedure to reinstall downdraft blowermotor (select models).Downdraftblower motorassemblyBottom Access Panel1. Grasp top of bottom access panel and gently pulldown and out.2. Reverse procedure to reinstall bottom access panel.Indicator Lights1. Remove control panel, see "Control Panel" procedurefor removal.2. Label and disconnect wires from indicator light.3. Squeeze the two tabs on the indicator light body andgently pull to release from control panel.4. Reverse procedure to reinstall indicator light.Oven SensorMeatProbeBroil ElementBakeElementCoolingFanTransformerMeat Probe Receptacle (Select Models)1. Turn power off.2. Remove range from installation position, see“Removing and Replacing Range” procedure.3. Remove main top, see "Main Top" procedure forremoval.4. Remove nut securing meat probe receptacle to cavity.5. Reverse procedure to reinstall meat probe receptacle.Back Panel1. Remove power from unit.2. Remove range from installation position, see“Removing and Replacing Range” procedure.3. Remove screws securing upper back panel to unit.4. Remove screws securing outside edges of the backpanel to unit chassis.5. Reverse procedure to reinstall back panel.Cooling Fan1. Remove power from unit.2. Remove back panel, see "Back Panel" procedure.3. Label and disconnect wire terminals from cooling fan.4. Remove screws securing fan to range chassis.5. Reverse procedure to reinstall cooling fan.