in 1/16th increments or less at a time.Fence perpendicular to tableThe outfeed fence must also be perpendicular tothe table. This can be checked as follows:8. Place a square against the casting (L, Fig.10) and table.9. If adjustment is required, adjust setscrews N(Fig. 10).Alignment is complete when both fence castingsare coplanar (in-line) as shown in Figure 9 andthe outfeed fence is perpendicular to the table.10. Replace both fences and secure.Ram Dial CalibrationThe cutter guard should be removed or raised toprovide clearance.Referring to Figure 11:1. Loosen the ram dial lock knob (B).2. Adjust the outfeed ram dial (A) fullyclockwise.3. With a straightedge (F) pressed against bothinfeed and outfeed fences (D, E, G) asreference, both fences should be in-line asshown and the scale (C) should indicate zero.If step 3 can be successfully achieved, nocalibration is required.If the fences cannot be brought into alignment (L),adjust as follows:4. Remove fences (D, E).5. Using a 10mm wrench, loosen the lock nut(O, Fig. 10) that secures the zero stop set-screw (P, Fig, 10) on the casting (L, Fig. 10).6. Loosen or tighten the setscrew (P, Fig. 10),as required, to bring fence castings intoalignment as shown in M.Note: Ram Dial Adjust (A) is fully clockwise(from step 2).7. Tighten lock nut (O, Fig. 10).If the scale (C) does not indicate zero:8. Loosen two screws (J) that secure theindicator (H) and adjust until the zero on theindicator (H) is lined up with the zero on thescale (K).9. Tighten screws (J).Repeat steps 2 and 3 to verify that calibration isFigure 1113