40 English 5.906-590.0 Rev. 01 (05/17) ABGL Uninstall / install appliance cover on the left side ADAT Open / close carrier1 Screws2 Holder solenoid valves3 Covers4 Nuts5 Covering plate Unscrew the screws. Remove the holder for the solenoid valves. Put the solenoid valves to the side. Remove covers. Loosen the mounting nuts. Remove the covering plate.1 Electric socket plug connections2 Low-water thermostat3 Cable tie4 Screw connections5 Probe thermostat water shortage6 Steam boiler Lift the steam boiler. Disconnect screw connections. Separate the electric connectors. Remove the cable ties. Pull the probe of the water shortage thermostat out ofthe steam boiler. Remove the thermostat water shortage.1 Low-water thermostat2 Bracket3 Nut4 Cover cap Remove the cover cap. Loosen the nut. Remove support.Installation informationInsert the probe thermostat water shortage all the way tothe stop.ADTW Uninstall / install water shortage thermostat