68 English 5.906-590.0 Rev. 01 (05/17)Table of measurement valuesError codes Component Connec-torMeasured between:Pin : PinTargetvalueCorrectionE1 Probe waterlevelExchangethermostatprobe.X6 2 : GND Check electric cable for water levelprobe for continuity. Check water level probe, and exchangeif necessary. Check plug contact for power electron-ics to μc-card (ribbon cable). Reset fault by means of reset button. Replace μc-card.E3 Reed contactfresh watertankX2 6 : 3 0V (tankfull/miss-ing)5V (tankempty) Check wiring for continuity. Check the connector. Replace μc-card.E4 Reed contactdetergenttankX2 6 : 2 0V (tankfull)5V (tankempty) Check wiring for continuity. Check the connector. Replace μc-card.E5 Reed contactwaste watertankX2 6 : 1 0V (tankempty)5V (tankfull/miss-ing) Check wiring for continuity. Check the connector. Replace μc-card.E12 Handle X4 7 : 8 Check wiring for continuity. Check the connector. Replace μc-card.E13 Handle X4 1 : 8 0-10 kΩ Check wiring for continuity. Check the connector. Replace μc-card.E16 Fan X5 1 : 2 24V (+-5%) Check fan, replace as necessary. Replace power electronics. Check plug contacts on the power elec-tronics (power card).General troubleshooting for steam vacuum cleaners and steamersCause CorrectionDoes not start. Check mains / fuse for house connection. Check the mains connection cable for damages. Check On/Off switch. Check the suction turbine. Check / replace circuit board. Empty the container (wet vacuuming) Check socket / microswitch. Check / clean overflow protection electrodes. Fusing too low (under 16 amps).No suction performance. Accessories dirty. Suction container / waste water container full / defective. Check the suction turbine. Blower filter dirty. Dirt filter for fresh water dirty. Reed contacts for filling level closed / active.