GB - 14Parameter Description3.3.2 Operating DisplayThe parameters below serve for the controlling of the frequency inverter during operation.CP.01 Actual frequency displayCo-domain Description0…±400 Hz Display of the actual output frequency in Hz. Additionally the operatordisplay "noP" and "LS", even if the control release or direction of rotationare not switched (see CP.03). The rotation of the inverter is displayed bythe sign. Examples:18.3 Output frequency 18,3 Hz, rotation forward-18.3 Output frequency 18,3 Hz, rotation reverseCP.02 Set frequency displayCo-domain Description0…±400 Hz Display of actually set value. For control reasons the set speed is dis-played, even if the control release or direction of rotation is not switched.If no direction of rotation is set, the set frequency for clockwise rotation(forward) is displayed.CP.03 Inverter stateThe status display shows the actual working conditions of the inverter. Possible displays andtheir meanings are:Display StatusnOP „no Operation“ control release not bridged; modulation switched off; outputvoltage = 0 V; drive is not controlled.LS „Low Speed“ no direction of rotation preset; modulation switched off; outputvoltage = 0 V; drive is not controlled.FAcc "Forward Acceleration" drive accelerates with direction of rotation forward.FdEc „Forward Deceleration“ drive decelerates with forward direction.rAcc "Reverse Acceleration" drive accelerates with direction of rotation reverse.rdEc "Reverse Deceleration" drive decelerates with direction of rotation reverse.Fcon "Forward Constant" drive runs with a constant speed and forward direction.rcon "Reverse Constant" drive runs with constant speed and reverse direction.Other status messages are described at the parameters, where they occur (see chapter 5„Error diagnosis“).