GB - 36Parameter Description3.5 Lift functionsDisplay Name Setting range Default settingLF.00 Parameter group Funct -LF.01 max. speed of system 0,000…15,000 m/s 0,000 m/sLF.02 Traction sheave diameter 0…2000 mm 600 mmLF.03 Gear reduction ratio multiplier 0,00…99,99 1,00/ 30,00LF.04 Gear reduction ration divisor 0,00...99,99 1,00LF.05 Factor rope suspension 1…8 1LF.06 Contract load 0…65535 kg 0 kgLF.10 Control mode 0…2 2LF.11 KP speed controller 0…32767 autoLF.12 KI speed controller 0…32767 autoLF.13 KI speed controller Offset 0…32767 autoLF.14 KP current controller 0…65535 autoLF.15 KI current controller 0…65535 autoLF.16 Boost 0,0…25,5 % 10,0 %LF.17 Autoboost on/off 0…1 autoLF.18 Autoboost / ampliciication 0,00…2,50 1,20LF.19 Filter time for current loop 0...5 3LF.20 VR releveling speed 0,000…0,300 m/s 0,000 m/sLF.21 V L leveling speed 0,000…0,300 m/s 0,000 m/sLF.22 V N nominal speed 0,000 m/s…LF.01 0,000 m/sLF.23 V I inspection speed 0,000…0,630 m/s 0,000 m/sLF.24 V 1 intermediate speed 1 0,000 m/s…LF.01 0,000 m/sLF.25 V 2 intermediate speed 2 0,000 m/s…LF.01 0,000 m/sLF.26 V 3 intermediate speed 3 0,000 m/s…LF.01 0,000 m/sLF.27 V U evacuation speed 0,000 m/s…LF.01 0,000 m/sLF.28 Setpoint value debounce time 0…127 ms 10 msLF.30 Starting jerk 0,10…9,99 m/s³ 0,50 m/s³LF.31 Acceleration 0,10…2,00 m/s² 0,90 m/s²LF.32 Jerk at end of acceleration 0,10…9,99 m/s³ 1,00 m/s³LF.33 Jerk at begin of deceleration 0,10…9,99 m/s³ 1,00 m/s³LF.34 Deceleration 0,10…2,00 m/s² 0,90 m/s²LF.35 Jerk at end of deceleration 0,10…9,99 m/s³ 0,70 m/s³LF.36 Stopping jerk 0,00…9,99 m/s³ 0,40 m/s³LF.40 Brake release time 0,00…3,00 s 0,25 sLF.41 Brake engage time 0,00…3,00 s 0,25 sLF.42 Switching threshold brake deactivation 0,000…0,010 m/s 0,005 m/sLF.43 Level overspeed 0,000…18,000 m/s 1,1•LF.1LF.44 Deceleration check 0,000…15,000 m/s 0,95•LF.22LF.45 Level „running open doors“ 0,000…0,300 m/s 0,250 m/sLF.46 Speed deviation mode 0…1 0LF.47 Spedd deviation level 0…30 % 10 %LF.48 Speed deviation tripping time 0,000…10,000 s 3,000 sLF.49 Motor + inverter OH-function 0…1 0LF.50 drive OH delay time 0…120 s 0 sLF.51 Standstill control 0,00...8000,00 rpm autoLF.52 KP start amplification 0…32767 1100 or LF.11LF.53 KP start timer -0,01(oFF)…50000,00 s -0,01 = oFFLF.60 Display levelling path 0,0...264,0 cm -LF.61 Levelling path optimization V N 0,0…200,0 cm 0,0 cmLF.62 Levelling path optimization V 1 0,0…200,0 cm 0,0 cmLF.63 Levelling path optimization V 2 0,0…200,0 cm 0,0 cmLF.64 Levelling path optimization V 3 0,0…200,0 cm 0,0 cmLF.65 Levelling path optimization V L 0...300 mm 0 mm