30Copyright © 2000 - 2005 KEMP Technologies, Inc. All Rights Reserved.Hint: To enable a syslogd process on a remote Linux server to receive syslog messages from the LoadMaster,the syslogd must be started with the “-r” flag.2. How to get a licenseAfter boot, a login prompt appears; login as ‘bal’ (password ‘1fourall’).To unlock the LoadMaster software you need a license key. The license key will be generated individually foreach single LoadMaster instance in conjunction with a hardware dependent Access Code.There are three different licenses that you can get for your LoadMaster:a) An evaluation license. This is a fully functional license valid for up to 30 days.b) A full, non time-limited LoadMaster license.c) A full, non time-limited license for a LoadMaster High Availability (HA) cluster consisting of two machines.An evaluation license can be upgraded to either a full single or a full HA license.2.1. Get a 30 day evaluation license1. Using a null modem cable connect a PC using terminal emulation software from its COM+ port to theLoadMaster COM+ port (COM+ settings should 115200,8,N,1). After boot, a login prompt appears; login as‘bal’ (password ‘1fourall’), and your Access Code will be displayed on the screen.2. If not already provided contact your KEMP Technologies Representative to obtain evaluation license. Besure to provide the Access Code (or codes if HA), so the evaluation license can be “mapped” to the unit(s).Customer contact should have provided KEMP with a valid email address to send license to Customer contact.2.2. Get a full LoadMaster license1. A service agreement upon purchase must be approved by KEMP in order to obtain a full LoadMasterappliance.2. Using a null modem cable connect a PC using terminal emulation software from its COM+ port to theLoadMaster COM+ port (COM+ settings should 115200,8,N,1). After boot, a login prompt appears; login as‘bal’ (password ‘1fourall’), and your Access Code will be displayed on the screen.3. If not already provided contact your KEMP Technologies Representative to obtain evaluation license. Besure to provide the Access Code (or codes if HA), so the evaluation license can be “mapped” to the unit(s).Customer contact should have provided KEMP with a valid email address to send license to Customer contact.2.3. Get full High Availability LoadMaster cluster licenses1. A service agreement upon purchase must be approved by KEMP in order to obtain a full LoadMaster HAlicense.2. Using a null modem cable connect a PC using terminal emulation software from its COM+ port to theLoadMaster COM+ port (COM+ settings should 115200,8,N,1). After boot, a login prompt appears; login as‘bal’ (password ‘1fourall’), and your Access Code will be displayed on the screen.3. If not already provided contact your KEMP Technologies Representative to obtain evaluation license. Besure to provide the Access Code (or codes if HA), so the evaluation license can be “mapped” to the unit(s).Customer contact should have provided KEMP with a valid email address to send license to Customer contact.Note: TPS Limits for SSL acceleration (100 default, 400, 700, 1000) will be determined upon serviceagreement. Please contact you KEMP representative for more information and pricing.Note: The License Keys and Access Codes are NOT interchangeable between machines.