7.7 Manual totalizingWith this function the individual weighing values are added into the summationmemory by pressing and edited, when an optional printer is connected.• Menu settings:„P1 COM“ Ö „MODE“ Ö „PR2““, s. Kap. 8• The totalisation function is not active when the weight is under 20d.Add up:Ö Place goods to be weighed A.Wait until the stability display STABLE appears, then press . The weight valuewill be saved and a printout received if an optional printer is connected.Ö Remove the weighed good. More weighed goods can only be added when thedisplay = zero.Ö Place goods to be weighed B.Wait until the stability display appears, then press . The weight value will beadded to the summation memory and possibly printed. The number of weighingprocesses followed by the total weight will be shown for 2 sec.Ö Add more weighed goods as described before.Please note that the weighing system must be unloaded between the individualweighing procedures.Ö This process can be repeated until the capacity of the weighing system isexhausted.Display of the saved weighing data:Ö Press and the number of weighings followed by the total weight will beshown for 2 sec. To receive a printout, press during this display.UFB/UFN-BA-e-1011 21