14PROGRAMMING WITH MANUAL OVERRIDESWITCHYour Timer may have a 3-way manual switch or a2-way manual switch.AUTOMATIC MODEIn order to operate the time clock in the automaticmode, the manual switch must be in the automaticpostion- see diagram.MANUAL MODEFor the 3-way switch, with the manual override switchin the lower position, marked “O”, the time clockoutput will remain Permanently OFF. In the upperposition, marked “I”, the time clock output will remainpermanently ON.For the 2-way switch, with the manual override switchin the lower position, marked “ON” the time clockoutput will remain permanently ON.7-Day (SW, QRW Models)7-Day (SW, QRW Models)AUTOMATIC MODEMANUAL MODEOverride Mode3-way manualoverride switchI = permanent ON= automatic0 = permanent OFFONAUTOSETTING THE TIMERThe timer is a 24 hour time clock with 15 minute increment settings.The captive trippers change the SPDT relay state when pushedtoward the outside.1. Setting time of day(a) Synchronize the timer by aligning arrow at the 2:00 positionof inner face with the corresponding time of day printed on theouter ring.NOTE: Power must be ON to keep time synchronization.2. Setting ON time and durationLocate desired activation time(s) on outer ring (b) and pushtrippers to the outside (c). Each tripper represents 15 minutesactivation time. Push as many trippers back as desired for dura-tion time. When the timer reaches the first tripper, the timer SPDTcontacts will change state and turn ON. It will remain ON for aslong as the following trippers are pushed out. When timer goespast last tripper, the timer will return to the OFF mode. The timerhas a selector for (d) AUTOMATIC and ON modes.Overide Mode2-way manual ON - Permanently ONoveride switch AUTO - automaticC85 / C95 non-metallic and 3 PhaseControl Panel TimerTIME CLOCK SETTINGTo set the current time, turn the inner dial clockwise.Do not set the time by rotating “outer” dial.Turn the minute hand or small plastic inner dial clock-wise until the time of day on the outer dial is alignedwith the triangle marker on the inner dial (two o’clockposition).Example for 10:00 AM. Turn the minute hand clock-wise until 10:00 AM is aligned with the triangle onthe inner dial. The hour and the minute dial will showexactly 10:00.Triangle markerCaptive trippers(in the on position)PROGRAMMINGThe 24-Hour dial has quarter-hour divisions and AM/PM indications.The time switch is programmed by pushing the captivetrippers to the outer ring position for the entire pe-riod that the aerator is to be turned “ON”, i.e., fifteenminutes for each tripper on the 24-Hour dial. Whenthe tripper is pushed to the inside, the switch is in the“OFF” position.