12Problem Probable Cause SolutionMain power light does not come on. a.Fryer not plugged in.b.Breaker has tripped.c. Main power switch is faulty.a.Plug fryer into approved outlet. Mustbe properly grounded.b.Reset the breaker lcoated on thebottom of the control panelc. Replace the main power switch.Blower light does not come on. a.Thermostat not turned on.b.If blower comes on, blower light isfaulty.c. If Over Maximum Temperature light ison, Hi-Limit has been activated.d.If unit has a filter, drain handle notlocked into place.a.Set thermostat to desiredtemperature.b.Replace blower light.c. Reset Hi-Limit after oil has cooleddown below 425°F. Correct problemwhich caused Hi-Limit to activate(See page 10).d.Secure drain handle in placebehind the bracket.Burner light does not come on. • Check for flame at each burner. Ifno flame is present at either burner:a.Spark module is faulty.• Check for flame at each burner. Ifflame is present at both burners:b.Burner light is faulty.a.Replace spark module.b.Replace burner light.Burner light comes on, then goesout (after 2 1/2 seconds).• Check for spark at each burner. Ifno spark at either burner:a.Spark electrode wires are not tight orfaulty.b.Spark electrode is faulty or is outof alignment.• Check for spark at each burner. Ifspark occurs at both burners:c. Gas is not hooked up properly ornot turned on.d.Spark electrode is faulty or is outof alignment.e.Combination gas valve is faulty.a.Tighten spark electrode wires orreplace.b.See detail on page 26.c. Turn manual gas valve on. If usingflexible connector with quickdisconnect, make sure that the quickdisconnect is completely engaged.d.Align spark electrode. Replace sparkelectrode if faulty. Gap must be 1/8"between electrode and pilot tube andbetween pilot tube and burner (Seepage 26).e.Replace combination gas valve afterverifying it has voltage.TROUBLESHOOTING CHARTThe following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that youuse a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified servicecompany.NOTE: To correctly and quickly diagnose the system, the chart below must be followed in sequential order.