© KEMPPI OY16 – MASTER MLS™ 1600, MASTERTIG MLS™ 2000 / 0530MTM, MINILOG 6116010MEX, MMA 6106010OptionalTIG torch controlsRTC 10 6185477RTC 20 6185478Remote controlR 10 6185409R11F 6185407R11T 6185442Transport unitT100 6185250T110 6285251T130 61852224.3. TROUBLESHOOTINGMain power on light is not onThere is no power in the machine Check mains fuses, replace blown fuses. Check mains cable and plug, replace defect parts.The machine is not welding properly.There are plenty of spatters during welding. Weld joint is porous, power supply is insufficient. Check welding settings and adjust if needed. Check gas flow and gas hose connection. Check that earth cable is properly fastened and has no defects. Change the position ifnecessary and replace defect parts. Check welding torch cable and connector. Tighten the connection and replace defectiveparts. Check the wear parts of welding torch. Clean and replace defect parts. Check mains fuses, replace blown fuses.Power source overheat signal lamp is lit.Power source is overheated. Check that there is enough free space behind the machine for cooling air circulation.For further information and assistance, contact your nearest Kemppi service workshop.4.4. DISPOSAL OF THE MACHINEDo not dispose of electrical equipment together with normal waste!In observance of European Directive 2002/96/EC on Waste Electrical and ElectronicEquipment and its implementation in accordance with national law, electrical equipmentthat has reached the end of its life must be collected separately and returned to anenvironmentally compatible recycling facility. As the owner of the equipment, you shouldget information on approved collection systems from our local representative.By applying this European Directive you will improve the environment and humanhealth!