Minarc T 223 ACDCOperating manual - ENWater cooling OFF/Auto/ONDefault = AutoWhen ON is selected, the coolant is cir-culated continuously, and when Auto isselected, the coolant is circulated onlyduring welding.Remote control min Min = Current limit minimumMax = Current limit maximumMinimum and maximum welding currentlimits for remote control.Remote control maxMMA welding parametersThe parameters listed here are available for adjustment with the MMA welding process.Parameter Parameter value DescriptionHot start level -10 ... +10, step 1Default = 0Welding function that uses higher orlower wire feed speed and welding cur-rent at the start of the weld. After the Hotstart period the current changes to nor-mal welding current level. This facilitatesthe start of the weld especially with alu-minum materials.VRD ON/OFFDefault = OFF(In AU power source models VRD islocked ON)Voltage reduction device (VRD) reducesthe open-circuit voltage to maintainbelow a certain voltage value.Remote control min. Min = Current limit minimumMax = Current limit maximumMinimum and maximum welding currentlimits for remote control.Remote control max.Cleaning and polishing parametersThe parameters listed here are available for adjustment with the cleaning and polishing processes.Parameter Parameter value DescriptionWater cooling OFF/Auto/ONDefault = AutoWhen ON is selected, the coolant is cir-culated continuously, and when Auto isselected, the coolant is circulated onlyduring cleaning and polishing.Remote control min. Min = Current limit minimumMax = Current limit maximumMinimum and maximum current limitsfor remote control.Remote control max.3.2.3 Memory channelsEach process (TIG, MMA, cleaning and polishing) has 4 memory channels available.© Kemppi 34 1922350 / 2413