14 – Promig 100/0601 © KEMPPI OY3. CONTROL PANEL OPERATIONSWelding method selection (S1): MIG / MMA (MIG two-sequence procedure or four-sequenceprocedure is determined according to mode selection of the Promig 501, 501L and 530.Control mode selection: (S2) local control / remote control, (S3) remote control unit / guncontrol unitLocal controls: wire feed speed/MMA current (R1), welding voltage (R2)Warning light for thermal shield (H11)3.1. WELDING METHOD SELECTING SWITCHMMAMMA welding with stepless welding current controlMIGMIG welding, the switch of the Promig 100 must be on this position whenthe MIG welding is startedMIG two-sequence procedure is selected on the Promig 501, 501L and 530 panel.MIG/MAG welding with two-sequence procedure of welding gun start switch.1. switch pressed: welding starts2. switch open: welding stopsMIG four-sequence procedure is selected on the Promig 501, 501L and 530 panel.MIG/MAG welding with four-sequence procedure of welding gun start switch.1. switch pressed: shielding gas flow starts2. switch open: welding starts3. switch pressed: welding stops4. switch open: shielding gas flow stopsLocal control: Control potentiometers R1 and R2 on panel are used.Remote control: Adjustments are carried out from remote control unitR20 which is connected to remote control connector X4 of subfeeder.If you use the remote control unit R10, adjust wire feed speed or MMA weldingcurrent with potentiometer of the R10 and voltage with potentiometer U on panel.Gun control: Wire feed speed is adjusted with control module RMT which isconnected to Kemppi PMT welding gun and welding voltage is adjusted withpotentiometer U on panel.3.2. THE PROMIG 501, 501L AND 530 HAS THE MC CONTROL PANELControl mode selecting switch