Promig 100/0601 – 17© KEMPPI OY6. SERVICE, OPERATION DISTURBANCESThe amount of use and the working environment should be taken into consideration whenplanning the frequency of maintenance of Promig.Careful use and preventive maintenance will help to ensure trouble-free operation.The following maintenance operations should be carried out at least every six months:Check:- The wear of the grooves of the feed rolls. Excessive wear of groo-ves causes problems in wire feed.- The wear of the wire guide tubes of wire feed. Badly worn feedrolls and wire guide tubes should be discarded.- The wire guide tube in the gun connector should be set as nearthe feed rolls as possible, but not touching them and the wire mustfollow a straight line from the end of the tube to the groove ofthe feed roll.- Reel brake adjustment- Electric connections* oxidized couplings must be cleaned* loose couplings must be tightenedClean dust and dirt from the equipment.When using compressed air, always protect your eyeswith proper eye protection.In case of problems contact the Kemppi works in Lahti, Finland or your Kemppi dealer.twice ayear7. ORDERING NUMBERSPromig 100 6236305Promig 501 6231501Promig 501L 6232505Promig 530 6232530Prosync 50 6263121Pro 3200 6131320Pro 4200 6131420Pro 5200 6131520Procool 10 6262012Procool 30 6262016P40 6185264P30W 6185409RMT10 6185475R10 6185409R20 61854195 /0,95 m 42693408 /1,5 m 426903016d/10 m 618548120 /5 m - 50 mm2 618451120 /5m - 70 mm2 618471121 /5 m - 50 mm2 618450121 /5m - 70 mm2 6184701Hub for wire reel 4289880