NX-82052ADJUSTMENT(Power ON)Market codeSquelch levelChannel No.Signaling No.AW : Analog wide modeAN : Analog narrow modeNN : NXDN narrow modeNV : NXDN very narrow modeFrequency range“UHF F2”: 400~470MHz(After 2sec.)Function Low power• LED indicatorRed LED Lights during transmission.Green LED Lights when there is carrier.• LCD display in panel test mode■ Frequency and SignalingThe transceiver has been adjusted for the frequenciesshown in the following table. When required, readjust themfollowing the adjustment procedure to obtain the frequenciesyou want in actual operation.• Test frequencyCH RX (MHz) TX (MHz)1 435.05000 435.100002 400.05000 400.100003 469.95000 469.900004 435.00000 435.000005 435.20000 435.200006 435.40000 435.400007~16 - -• Analog mode signalingNo. RX TX1 None None2 None 100Hz Square Wave3LTR Data:AREA=0, GOTO=12HOME=12ID=47, FREE=25LTR Data:AREA=0, GOTO=12HOME=12ID=47, FREE=254 QT: 67.0Hz QT: 67.0Hz5 QT: 151.4Hz QT: 151.4Hz6 QT: 210.7Hz QT: 210.7Hz7 QT: 254.1Hz QT: 254.1Hz8 DQT: D023N DQT: D023N9 DQT: D754I DQT: D754I10 DTMF: 159D DTMF: 159D11 None DTMF Code 912 2-tone:A: 304.7Hz, B: 3106.0Hz2-tone:A: 304.7Hz, B: 3106.0Hz13 Single Tone: 979.9Hz Single Tone: 979.9Hz14 None Single Tone: 1000Hz15 None MSK PN916 MSK MSK