NXR-80071ADJUSTMENTTest Equipment Required for AlignmentTest Equipment Major Specifications1. Standard Signal Generator(SSG)Frequency Range 400 to 512MHzModulation Frequency modulation and external modulationOutput 0.1μV to greater than 1mV2. Power MeterInput Impedance 50ΩOperation Frequency 400 to 512MHz or moreMeasurement Capability Vicinity of 100W3. Deviation Meter Frequency Range 400 to 512MHz4. Digital Volt Meter (DVM) Measuring Range 1V to 20V DCInput Impedance High input impedance for minimum circuit loading5. Oscilloscope DC through 30MHz6. High SensitivityFrequency CounterFrequency Range 10Hz to 600MHzFrequency Stability 0.2ppm or less7. Ammeter 15A or more8. AF Volt Meter (AF V.M) Frequency Range 50Hz to 10kHzVoltage Range 3mV to 3V9. Audio Generator (AG) Frequency Range 50Hz to 5kHzOutput 0 to 1V10. Distortion Meter Capability 1% or less at 1kHzInput Level 50mV to 10Vrms11. Voltmeter Measuring Rnage 10V to 1.5V DC or lessInput Impedance 50kΩ/V or greater12. 4Ω Dummy Load Approx. 4Ω, 5WCutHOOK(GRY)MIC (WHT)MICG (SHIELD)toAGAF VTVM PTT(BLU)GND(BLK)PTT SWPlug cordPart No. E30-3360-188 pin8 pinMIC connector (Front panel view)Jig for MCF adjustment (W05-1000-00)Test cable for microphone input (E30-3360-18)811: NC2: SB3: GND4: PTT5: MIG6: MIC7: HOOK8: NC