NXR-80079ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications / RemarksTest-equipment Unit Terminal Unit Parts Method32. QTDeviation1) Analog WideConnect the deviation meterto the TX ANT end via theATT.Deviation meter settingHPF: OFFLPF: 3kHzDe-emp: OFFDetector: p-p/2DeviationmeterRear TX ANT PCADJ±0.75kHz ±0.05kHz2) Analog Narrow ±0.35kHz ±0.05kHz33. DQTDeviation1) Analog WideConnect the deviation meterto the TX ANT end via theATT.Deviation meter settingHPF: OFFLPF: 3kHzDe-emp: OFFDetector: Peak holdDeviationmeterRear TX ANT PCADJ±0.75kHz ±0.05kHz2) Analog Narrow ±0.35kHz ±0.05kHz34. CW IDDeviation1) Analog WideConnect the deviation meterto the TX ANT end via theATT.Deviation meter settingHPF: OFFLPF: 15kHzDe-emp: OFFDetector: +peak, –peakDeviationmeterRear TX ANT PCADJ±2.00kHz ±0.05kHz2) Analog Narrow ±1.00kHz ±0.05kHz35. Test ToneDeviation1) Analog WideConnect the deviation meterto the TX ANT end via theATT.Deviation meter settingHPF: OFFLPF: 15kHzDe-emp: OFFDetector: (p-p)/2DeviationmeterRear TX ANT PCADJ±3.00kHz ±0.05kHz2) Analog Narrow ±1.50kHz ±0.05kHz36. DTMFDeviation1) Analog WideConnect the deviation meterto the TX ANT end via theATT.Deviation meter settingHPF: OFFLPF: 15kHzDe-emp: OFFDetector: (p-p)/2DeviationmeterRear TX ANT PCADJ±2.85kHz ±0.05kHz2) Analog Narrow ±1.50kHz ±0.05kHz