TK-2200L18ADJUSTMENT5. Max deviation TEST CH: Center Power meter ANT Programming 4.2kHz ±80HzAdjust Low Deviation meter SP/MIC connector Software:KPG-88D (According to[Wide] High Oscilloscope the larger +,–)(3 points) AGAG:1kHz/150mV AF VTVMDeviation meter filterLPF:15kHzHPF:OFFPTT:ON[Narrow] TEST CH:Center 2.2kHz ±80HzPTT:ON (According tothe larger +,–)6.VOX 1 TEST CH:CenterWriting AG:1KHz/45mV7. QT deviation TEST CH: Center ANT Programming 0.80kHz ±40HzAdjust Low Software:KPG-88D[Wide] High(3 points)LPF:3kHzHPF:OFFPTT:ON[Narrow] TEST CH: Center 0.40kHz ±40HzPTT:ON8.DQT deviation TEST CH: Center 0.75kHz ±40HzAdjust Low[Wide] High(3 points)LPF:3kHzHPF:OFFPTT:ON[Narrow] TEST CH:Center 0.40kHz ±40HzPTT:ON9.DTMF deviation TEST CH:Center 3.0kHz ±100HzAdjust LPF:15kHz[Wide] HPF:OFFPTT:ON[Narrow] TEST CH:Center 1.5kHz ±100HzPTT:ON10.MSK deviation TEST CH: Center 3.0kHz ±100HzAdjust Low[Wide] High(3 points)LPF:15kHzHPF:OFFPTT:ON[Narrow] TEST CH:Center 1.5kHz ±100HzPTT:ONItem Condition Measurement Adjustment Specifications/Test equipment Terminal Parts Method Remark