44TK-39011. QT 1) Set panel tuning mode Power meter Panel ANT Panel Top1/ 0.75kHz ± 0.05kHzdeviation CH No. : 3 Deviation Top2adjustment Signalling No. : 1 meter(wide) MIC input : OFF OscilloscopeSelect QTDV ∗ ∗ ∗in panel tuning mode AG Side UniversalDeviation meter filter setting AF VTVMLPF : 3kHzHPF : 50HzDe-emphasis : 750μsPTT : ON12. QT 1) Set panel tuning mode 0.375kHz ± 0.05kHzdeviation CH No. : 3adjustment Signalling No. : 1(narrow) MIC input : OFFSelect QTDV ∗ ∗ ∗in panel tuning modeTurn the toggle SW to theright (narrow)Deviation meter filter settingLPF : 3kHzHPF : 50HzDe-emphasis : 750μsPTT : ON13. DQT 1) Set panel test mode 0.75kHz ± 0.05kHzdeviation CH No. : 3adjustment Signalling No. : 1(wide) Select DQDV ∗ ∗ ∗in panel tuning modeDeviation meter filter settingLPF : 3kHzHPF : OFFPTT : ON14. DQT 1) Set panel tuning mode 0.375kHz ± 0.05kHzdeviation CH No. : 3adjustment Signalling No. : 1(narrow) Select DQDV ∗ ∗ ∗in panel tuning modeTurn the toggle SW to theright (narrow)Deviation meter filter settingLPF : 3kHzHPF : OFFPTT : ON15. DTMF 1) Set panel test mode 3.0kHz ± 50Hzdeviation CH No. : 3adjustment Signalling No. : 1(wide) Select DTDV ∗ ∗ ∗in tuning modeDeviation meter filter settingLPF : 15kHzHPF : OFFPTT : ONMeasurementTest-equipment Unit TerminalAdjustmentUnit Parts Method Specifications/RemarksConditionItem