71ADJUSTMENTMeasurementTest-equipment Unit TerminalAdjustmentUnit Parts Method Specifications/RemarksConditionItemTK-790/(B)/H(B)• Med power 1) CH-SIG : 1-1 Power meter Rear ANT TX-RX VR1 Maximum clockwise 47W or lessmodel Select _POW_XXX Ammeter (C/3)(High power) in tune mode 45W adj. 45W±1W, 12A or lessPTT : ONPanel PF3 key Check 45W±1WPF4 key(Low power) 1) CH-SIG : 1-1 5W adj. 5W±1WSelect LPOW_XXXin tune modePTT : ON9. Maximum 1) Select _ _L Power meter Rear ANT Panel PF3 key Wide ±4.1kHz ± 0.1kHzdeviation MXDV_XXX Deviation PF4 key• Wide in tune mode meterPTT : ON AF VTVM Panel MICDeviation meter filter AGHPF : OFF OscilloscopeLPF : 15kHzDe-emphasis : OFFAG : 1kHz/50mV2) Select _ _CMXDV_XXXin tune modePTT : ON3) Select _ _HMXDV_XXXin tune modePTT : ON• Narrow 1) Up/down knob : Set the narrow Narrow ±2.05kHz ± 0.05kHzn_LMXDV_XXX in tune modePTT : ON2) Select n_CMXDV_XXXin tune modePTT : ON3) Select n_HMXDV_XXXin tune modePTT : ON10. MIC 1) CH-SIG : 1-1 TX-RX VR501 Check 2.75~3.25kHzsensitivity PTT : ON (B/3)Wide only Deviation meter filterHPF : OFFLPF : 15kHzDe-emphasis : OFFAG : 1kHz/5mV