13EN7.2.1 - Level 1 programming (ON-OFF functions)Table 9 - List of programmable functions in "Programming on power-up" modeN° Description ExampleL1 Variable sensitivity This function enables the user to enable or disable the sensitivity with which obstacles are detected.The factory setting of sensitivity is variable (L1 LED off): greater sensitivity in the case of low motorforce, and less sensitivity where the motor force increases. All with the aim of ensuring optimaldetection precision. Variable sensitivity can be disabled, and 3 "fixed" levels of motor force remain(L1 LED lit).L2 Phototest/Electric lock This function enables the user to enable output 8 of the terminal board for operation with phototestor with an electric lock. The factory setting of output 8 is with the "phototest" function enabled (L2LED off). Alternatively, the output can be programmed on the OVO control unit to control an electriclock (L2 LED lit).L3 Partial opening This function enables either a long or short partial opening interval to be selected. The factorysetting for partial opening is long (approx. 1 m, L3 LED lit). Alternatively, partial opening can be setto short (approx. 15 cm, L3 LED off).At the end of the "Programming on power-up" procedure, the L1, L2 and L3 LEDs indicate the status of the functions in "Standardprogramming" mode.Table 10 - List of programmable functions in "Standard programming" modeN° Description ExampleL1 Closing speed This function enables the selection of the motor speed during the closing manoeuvre, from 2 levels:"high" and "low”. The factory setting is "high" (L1 LED lit). Alternatively the function can be disabledto set the "low" speed (L1 LED off).L2 Opening speed This function enables the selection of the motor speed during the opening manoeuvre, from 2levels: "high" and "low”. The factory setting is "high" (L2 LED lit). Alternatively the function can bedisabled to set the "low" speed (L2 LED off).L3 Automatic closure This function enables automatic closure of the door after a programmed pause; the defaultPause Time is set at 30 seconds but may be changed to 15 or 60 seconds. The factory setting is"semiautomatic" as Automatic closure is disabled (L3 LED off).During normal operation of OVO, the L1, L2 and L3 LEDs are lit or off depending on the status of the associated function in "Standardprogramming" mode. For example, L3 is lit if the "Automatic closure" function is enabled. L1 also displays the status of the "radio" functionin the first 10 seconds after power-up.7.2.2 - Level 1 programming (ON-OFF functions)By default level 1 functions are set as shown in tables 9 and 10, but can be modified at any time as shown in the procedures below. Takecare during modification procedures, as there is a maximum time interval of 10 seconds between pressing one key and another; otherwisethe system exits the procedure automatically memorising the changes made up to that time.• To modify the ON-OFF functions in "programming on power-up" mode:01. Switch off OVO (for example, by removing the F1 fuse).02. Press and hold P2.03. Switch on OVO (for example, by inserting the F1 fuse).04. Wait for the flashing signal indicating control unit start-up and keep P2 pressed until L1 starts to flash (approx. 6s).05. Release the P2 key when the L1 LED starts to flash.06. Press P3 to move the flashing LED to the LED associated with the function to be modified.07. Press P2 to change the status of the function (short flash = OFF; long flash = ON)08. Wait 10s to exit the programming mode automatically after the maximum time interval.NB: points 6 and 7 can be repeated during the same programming phase to set other functions to ON or OFF• To modify the ON-OFF functions in “standard programming” mode:01. Press and hold P2 for approx. 3s.02. Release the P2 key when the L1 LED starts to flash.03. Press P3 to move the flashing LED to the LED associated with the function to be modified.04. Press P2 to change the status of the function (short flash = OFF; long flash = ON)05. Wait 10s to exit the programming mode automatically after the maximum time interval.NB: points 3 and 4 can be repeated during the same programming phase to set other functions to ON or OFF