Application Guide89PLM Series Operation Manual rev 1.1.910.6.3.4 Signal Degradation and LossA weak or degraded AES3 signal will exhibit no audible loss of quality as long as the robustness of thedata stream remains above the threshold required for internal error correction. As degradation approachesthe threshold, audible artifacts may be heard, including pops, clicks and momentary dropouts. Any suchindications require immediate attention, as often the window of acceptable data loss between artifacts andcomplete audio loss can be very narrow.As a precautionary measure four touring applications, it is advisable to configure all digital audio wiringprior to use. It is recommended that all cables be tested for error-free performance at lengths 20% to 25%greater than lengths to be used in the field in order to provide a comfortable margin of safety.10.6.4 External Signal Distribution Hardware10.6.4.1 Distribution AmplifiersDedicated distribution amplifiers for AES3 signals are available from several manufacturers. The most com-mon format is one input and six outputs. Digital distribution amplifiers are designed to refresh or reconstructthe signal as well making up for line losses.One type of distribution amplifier is a simple repeater, which restores the waveform shape and brings thesignal amplitude back up the required level. Some distribution amplifiers also offer a re-clocking feature,which also re-times the signal to prevent signal degradation from clocking errors known as jitter.Distribution amplifiers that offer re-clocking often make the feature optional as using re-clocking can intro-duce small additional amounts of latency, so should not be used unless necessary.10.6.4.2 Passive splittersIn some limited applications, a single AES3 input may be split into two signals using a simple passivesplitter. Splitters provide a convenient and low cost solution when only one additional signal is required, andin situations where cable lengths are short. Attenuation is minimal, but there is no refreshing of the signal.10.6.5 Additional Reference MaterialComplete technical information on the AES/EBU (AES3) standard can be downloaded from the AES website at http://www.aes.org/publications/standards/.