Page 12 2018-06-08LABvault-SDWeb InterfaceePRO-BUS SettingClick the “System” button to display the “System Management” screen and then click the “ePRO-BUS” tab. Click the“Enable” button to allow the LABvault-SD to receive PRO-BUS control commands over your Ethernet network froma NEXUS, UltraNEXUS, or UltraNEXUS-SDI server. Clicking “Disable” will prevent the LABvault-SD from receivingePRO-BUS commands.NOTE: Any LABvault-SD and NEXUS series server using the ePRO-BUS feature must be assigned a static IP addressand made available for UDP on Port 2000.“ePRO-BUS” Tab on “System Management” Web Interface ScreenSerial Port SettingThe serial port mode setting, accessed by clicking the “Serial Port” tab on the “System Management” screen, applies tothe bottom serial port on the back panel of the LABvault-SD chassis. “Host” mode allows the LABvault-SD to receiveserial control commands from supported, external devices connected to the bottom serial port. “Camera” mode is notcurrently supported. Currently, the LABvault-SD is automatically configured in the “Host” mode.“Serial Port” Tab on “System Management” Web Interface Screen