3.2.5 Parameter list* specific values for each pump; see table of pumps, Chapter 3.2.6; r = readable, w = writableNo. Designation Min. Max. Default Unit r/w Format Description1 Converter type 0 65535 0 r u16 136 = Turbo.Drive 4002 Software version 0 65535 10000 r u32 xx.yy: version, zz: correction index3 Actual frequency 0 65535 0 Hz r u16 Actual rotor frequency4 Actual intermediate 0 1500 30 0,1 V r u16 Actual intermediate circuit voltagecircuit voltage of the converter5 Actual current 0 150 0 0,1 A r u16 Actual motor current6 Actual electricalpower 0 65535 0 0,1 W r u16 Actual drive input power7 Actual motor -10 150 0 °C r i16 Actual value of the motortemperature temperature.8 Save data command 0 65535 0 /w i16 A write command with any valuesaves temporary data intononvolatile memory.11 Actual converter -10 150 0 °C r i16 Actual heat sink temperaturetemperature of the converter.16 Motor temperature 0 150 * °C r i16 Exceeding the motor temperaturewarning threshold warning threshold results in awarning.17 Nominal motorcurrent 5 60 * 0,1 A r u16 Maximum permissible motor current18 Maximum frequency 750 1200 * Hz r u16 Highest permissible frequency19 Minimum frequency 0 1200 * Hz r u16 Lowest permissible frequency20 Critical frequency 0 1200 * Hz r u16 Minimum frequency level. When thepump is accelerating this frequencymust be reached within themaximum passing time (P183).23 Pump type 0 255 * r u1624 Setpoint frequency 0 1200 * Hz r/w u16 Setpoint of the rotor frequency25 Normal operation 35 99 90 % r/w u16 Setpoint of the frequency dependentnormal operation levelOperation3117200492_002_A5 - 04/2011 - © Oerlikon Leybold Vacuum