Flex EM/EX HazLoc System Instruction ManualJune 2019Page 35 of 624.2.2 Output Relay Configurations4.2.2.1 Output Relay Types (EX System only)NOTE: The following relay types are not available with Flex EM systems.1. 3 output relays per motion – shared 2nd speed output relayOutput relays with Forward 1st speed (F1), Reverse 1st speed (R1) and Forward/Reverse 2nd speed (F/R2). Forward and Reverse 2nd speed (F/R2) share the sameoutput relay.2. 4 output relays per motion – separate 1st and 2nd speed output relaysOutput relays with Forward 1st speed (F1), Reverse 1st speed (R1), Forward 2ndspeed (F2) and Reverse 2nd speed (R2). Forward and Reverse 2nd speed withseparate output relays.4.2.2.2 Output Relay Actions at 2nd Speed (EX System only)The following relay configurations are not available with Flex EM systems. See Section4.2.4 on page 39 for instructions on how to set them with EX systems.1. 3 output relay configuration with Closed/Closed contact at 2nd speedAt 2nd speed, both 1st speed (F1 or R1) and 2nd speed (F/R2) output relays areclosed.F1 R1 F/R2F1 F2R1 R2F1 F/R2R1 R1F1 F/R2Forward 1st speed pushbutton pressed Forward 2nd speed pushbutton pressed↓ ↓