Contents - contact information
- important safety instructions
- Table Of Contents
- Table Of Contents
- Introduction
- Figure 1-1, Power Switch, Status LED and Accessory Connection Ports
- Features and Benefi ts
- Figure 1-3, Left Side Features
- How the MS-PAE Series Inverter/Charger Works
- Installation 2.0 Installation
- Figure 2-1, Simplifi ed Installation Diagram - Single Inverter
- Figure 2-2, Approved Mounting Positions
- Figure 2-3, MS-PAE Series Dimensions
- Grounding Inverters
- Table 2-1, AC Grounding Electrode Conductor Sizing
- Table 2-2, Equipment Grounding Conductor Sizing
- DC Wiring
- Figure 2-8, DC and Battery Temperature Sensor Wiring
- Table 2-3, Recommended DC Wire/Overcurrent Device
- Figure 2-9, Battery Hardware Installation
- Figure 2-11, Battery Temperature Sensor
- AC Wiring
- Figure 2-12, AC Terminal Block
- Figure 2-13, AC Wiring
- Inverter Warning Label
- Functional Test
- Operation 3.0 Operation
- Standby Mode
- Figure 3-3, Automatic 4-Stage Charging Graph
- Battery Temperature Sensor Operation
- Protection Circuitry Operation
- Start-Up
- Factory Default Values
- Table 4-1, Troubleshooting Guide
- Performing an Inverter Reset
- Overview
- Figure 5-1, Simplifi ed Installation Diagram - Multiple Inverters (stacked in parallel)
- Parallel System Connections and Components
- Specifi cations A.1 Specifi cations
- A.2 Effi ciency Graphs
- Optional Equipment/Accessories B.1 Optional Equipment/Accessories
- Table C-1, Typical Appliance Power Consumption
- C.2 Battery Bank Sizing Worksheet
- C.3 Battery Wiring
- Figure C-4, Battery Bank Wiring Examples (24-volt)
- Figure C-5, Battery Bank Wiring Examples (48-volt)
- Warranty and Service D.1 Limited Warranty
|
Page 47© 2009 Magnum Energy Inc.Figure C-5, Battery Bank Wiring Examples (48-volt)48 vo lt b at t ery b an k (o n e strin g o f eig h t 6- vo lt b at t eries w ired in series )6 vo ltb attery( 200 A h rs)6 vo ltb at tery( 200 A h rs)6 vo ltb at t ery( 200 A h rs)6 vo ltb att ery( 200 A h rs)over -cur rent pr otectiont o 48 VD Cin verter(t o t al cap acit y= 200 A h rs)6 vo ltb attery(200 A h rs)6 vo ltb at t ery( 200 A h rs)6 vo ltb at t ery( 200 A h rs)6 vo ltb at t ery( 200 A h rs)12 vo ltb at t ery(100 A h rs)12 vo ltb att ery(100 A h rs)48 vo lt b at t ery b an k (o n e st rin g o f f o u r 12 -vo lt b at t eries w ired in series )12 vo ltb att ery(100 A h rs)12 vo ltb att ery(100 A h rs)over -cur rent pr otectiont o 48 VD Cin verter( t o t al cap acit y= 100 A h rs)6 vo ltb at t ery(200 A h rs)6 vo ltb attery(200 A h rs)6 vo ltb att ery(200 A h rs)6 vo ltb att ery(200 A h rs)over-current protection6 vo ltb at t ery(200 A h rs)6 vo ltb at t ery(200 A h rs)6 vo ltb at t ery(200 A h rs)6 vo ltb at t ery(200 A h rs)6 vo ltb att ery( 200 A h rs)6 vo ltb att ery(200 A h rs)6 vo ltb att ery(200 A h rs)6 vo ltb attery(200 A h rs)t o 48 VD Cin verter( t o t al cap acit y= 400 A h rs)6 vo ltb at tery( 200 A h rs)6 vo ltb at t ery( 200 A h rs)6 vo ltb at t ery( 200 A h rs)6 vo ltb at t ery( 200 A h rs)48 vo lt b at t ery b an k ( p arallel t w o st rin g s o f eig h t 6-vo lt b at t eries w ired in series )12 vo ltb at t ery(100 A h rs)12 vo ltb att ery(100 A h rs)12 vo ltb att ery(100 A h rs)12 vo ltb att ery(100 A h rs)12 vo ltb at t ery(100 A h rs)12 vo ltb att ery(100 A h rs)48 vo lt b at t ery b an k ( p arallel tw o strin g s o f fo u r 12 - vo lt b atteries w ired in series )12 vo ltb att ery(100 A h rs)12 vo ltb att ery(100 A h rs)t o 48 VD Cin verter(t o t al cap acit y= 200 A h rs)over -cur r ent pr otection48-volt Battery Bank (two strings of 12-volt batteries wired in series and paralleled)48-volt Battery Bank (two strings of 6-volt batteries wired in series and paralleled)48-volt Battery Bank (one string of 12-volt batteries wired in series)48-volt Battery Bank (one string of 6-volt batteries wired in series)Appendix C - Battery Information
PreviousNext |