23movable range of laser line is factory adjusted within 1mm (0.04") from the side surface of blade.)To shift the laser line movable range further away fromthe side surface of blade, turn the two screwscounterclockwise after loosening the adjusting screw.Turn these two screws clockwise to shift it closer to theside surface of the blade after loosening the adjustingscrew.Refer to the section titled "Laser line action" and adjustthe adjusting screw so that the cutting line on yourworkpiece is aligned with the laser line.NOTE:• Check the position of laser line regularly foraccuracy .• Have the tool repaired by Makita authorizedservice center for any failure on the laser unit.Cleaning of the lens for the laser lightFor model LS1013L/LS1013FL only123006346If the lens for the laser light becomes dirty, or sawdustadheres to it in such a way that the laser line is no longereasily visible, unplug the saw and remove and clean thelens for the laser light carefully with a damp, soft cloth.Do not use solvents or any petroleum-based cleaners onthe lens.1006347To remove the lens for the laser light, remove the sawblade before removing the lens according to theinstructions in the section titled "Installing or removingsaw blade".Loosen but do not remove the screw which secures thelens using a screwdriver.Pull out the lens as shown in the figure.NOTE:• If the lens does not come out, loosen the screwfurther and pull out the lens again without removingthe screw.Replacing fluorescent tubeFor LS1013F/LS1013FL only1 23 415002028CAUTION:• Always be sure that the tool is switched off andunplugged before replacing the fluorescent tube.• Do not apply force, impact or scratch to afluorescent tube, which can cause a glass of thefluorescent tube to be broken resulting in a injury toyou or your bystanders.• Leave the florescent tube for a while immediatelyafter a use of it and then replace it. If not. You mayburn yourself.Remove screws, which secure Lamp Box for the light.Pull out the Lamp Box keeping pushing lightly the upperposition of it as illustrated on the left.Pull out the fluorescent tube and then replace it withMakita original new one.Replacing carbon brushes1001145Remove and check the carbon brushes regularly.Replace when they wear down to the limit mark. Keepthe carbon brushes clean and free to slip in the holders.Both carbon brushes should be replaced at the sametime. Use only identical carbon brushes.Use a screwdriver to remove the brush holder caps.Take out the worn carbon brushes, insert the new onesand secure the brush holder caps.1. Limit mark1. Pull out2. Push3. Lamp box4. Screws5. Fluorescent tube1. Lens for thelaser light1. Screwdriver2. Screw (onepiece only)3. Lens for thelaser light