Maintenance Section 412 Part Number 000007651 05/10MANITOWOC’S CLEANING TECHNOLOGYManitowoc Flake Ice Machines include technology that allows the initiation and completion of a cleaning or sanitizingcycle at the flip of a switch. This cycle will permit cleaning of all surfaces that come in contact with the waterdistribution system. Periodic maintenance must be performed that includes sanitizing the bin and adjacent surfaceareas, which are not contacted by the water distribution system.Depending on local water conditions Manitowoc recommends initiating preventative maintenance cleaningprocedures between the 6 month cleanings.This preventive maintenance removes mineral build-up from the evaporator, which results in peak efficiency andlower operating costs.This technology will also allow initiation and completion of a clean or sanitize cycle, after which the ice machineautomatically starts ice making again.Refer to the cleaning/sanitizing procedure for complete details.PREVENTATIVE MAINTENANCE CLEANING PROCEDUREUse Ice machine cleaner part number 000000084 only.This cleaner is used to remove lime scale or othermineral deposits. It is not used to remove algae or slime.Refer to “Cleaning/Sanitizing Procedure” for removal ofalgae and slime. To initiate a cleaning cycle usingManitowoc’s Cleaning Technology use the followingprocedure.Step 1 Set the toggle switch to the OFF position. Openthe bin door and remove the 2 thumbscrews and whiteplastic panel.Step 2 Disconnect the water inlet line by depressingthe stainless steel tab (refer to disassembly for cleaningfor procedure).Step 3 Move the toggle switch to the CLEAN position.Water will flow through the water dump valve and downthe drain. The flush, gear motor, speed, dump valve andwater solenoid lights will energize to indicate the icemachine is in the clean mode.Step 4 Wait about one minute or until the dump valvede-energizes. Lift the front cover on the water reservoirand add the proper amount of Manitowoc Ice MachineCleaner.Step 5 Reconnect the water inlet line by pushing ontofitting and snapping into locked position.Step 6 The ice machine will automatically time outflush and rinse cycles, and then stop. The flush lightremains energized until the toggle switch is moved to theOFF position. This entire cycle lasts approximately 11minutes.Step 7 Replace the white plastic panel and move thetoggle switch to the ice position.NOTE: Periodic cleaning must be performed on adjacentsurface areas not contacted by the water distributionsystem.Manitowoc recommends disassembling, cleaning andsanitizing the ice machine and bin/dispenser every sixmonths.NOTE: The ice machine may be set to start and finish acleaning procedure, and then automatically start icemaking again. Wait about one minute into the cleaningcycle (until the dump valve light de-energizes), thenmove the switch from CLEAN to ICE position. When theclean cycle is complete ice making starts automatically.Model Amount of CleanerPart Number 000000084QF0406A 3 ounces (90 ml)